S p e c i f i c a t i o n s
Select
Model:
-
STO-P
UPS 40:
Power Fault Protector and UPS BackUp Power Supply providing 40 Amps of safe power. An internal backup battery is supplied - housed in a rugged diecast case sealed to IP65 standards. An external battery may be used for even greater backup capacity.
-
STO-P
PFP15:
Power Fault Protector, UPS enabled but requires user supplied backup
battery mounted externally. Provides 15 amps of safe power.
Specifications:
 STO-P UPS 40 Electronic
Fault Protector
| Technical
Specs for Model: |
STO-P
UPS 4012-x
|
STO-P
UPS 4024-x
|
| Nominal
Voltage: |
12
VDC
|
24/28
VDC
|
| Operational
Range: |
0-15
VDC
|
0-30
VDC
|
| Max.
Continuous Current |
40
Amps
|
30
Amps
|
| Short
Term Current |
60
Amps ( 30 Secs )
|
40
Amps ( 90 Secs )
|
| Overvoltage
Limit: |
+15.3
VDC (adjustable)
|
+30.5
VDC (adjustable)
|
| Reverse
Polarity Clamping |
-
0.5 VDC ( typ.)
|
-
0.5 VDC ( typ.)
|
| Transient
Response time |
1
nanosecond ( typ.)
|
1
nanosecond ( typ.)
|
| Internal
Backup Battery |
1.2,
or 4.0 Ah
|
1.2
Ah
|
| Peak
'Fill-in' Current |
45
Amps
|
45
Amps
|
| External
Battery Option? |
Yes!
|
Yes!
|
| Operating
Temperature |
-40C
to +85C
|
-40C
to +85C
|
| Input/Output
Leads |
8
AWG/7mm2 FlexCopper
|
8
AWG/7mm2 FlexCopper
|
| Dimensions
LWH (mm) |
190L
x 110W x 120H
|
190L
x 110W x 120H
|
| Models: |
UPS
4012-1 (1.2 Ah Battery) 12 Volts |
|
UPS
4012-4 (4 Ah Battery) 12 Volts |
|
UPS
4024-1 (1.2 Ah Battery) 24 Volts |
| Availability: |
Stock
to 30 days |
STO-P PFP15 Specifications:

STO-P EFP 15 Electronic
Fault Protection
Uninterruptible Power
Supply (U.P.S.) Enabled
| |
| TECHNICAL
SPECS: |
Model PFP151224
or
Model EFP151224 |
| Setting: |
12 Volt
D.C. |
24 Volt
D.C. |
| Nominal
Voltage: |
12 VDC |
24/28 VDC |
| Operational
Range: |
0-15 VDC |
0-30 VDC |
| Maximum
Continuous Current: |
15.0 Amps |
15.0 Amps |
| Nominal
Trigger Point: |
16.5 VDC |
30.5 VDC |
| Spike Suppression
Threshold |
-1/+18 VDC |
-1/+36 VDC |
| Dimensions-LWH
(mm) |
50x50x30 |